Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Braz. J. Pharm. Sci. (Online) ; 58: e20492, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1420382

ABSTRACT

Abstract The objective of this study was to evaluate the influence of vitamin C (VC) on the stability of stored liposomes under different climatic conditions. Liposomal formulations containing 1 mg/mL of VC (LIP-VC) and blank formulations (LIP-B) were prepared by the reverse-phase evaporation method. After preparation, they were characterized according to their refractive index, average vesicle diameter, polydispersity index (PDI), zeta potential, pH, content, encapsulation efficiency (EE%), morphology, stability and antioxidant activity. For stability, LIP-VC and LIP-B were stored in different climatic conditions (4 °C, 25 °C and 40 °C) for 30 days. The LIP-VC presented 1.3365 refractive index, 161 nm of mean diameter, 0.231 PDI, -7.3 mV zeta potential, 3.2 pH, 19.4% EE%, spherical morphology, 1 mg/mL of VC content, and antioxidant activity of 12 and 11.4 μmol of TE/mL for the radical DPPH and ABTS+, respectively. During stability, the LIP-B stored in 40 °C showed an instability in the parameters: PDI, vesicle size and zeta potential after 15 days, while the LIP-VC remained stable in its size and PDI for 30 days. After that, it is shown that VC can be used as an antioxidant and stabilizer in liposomes to increase the stability and shelf-life of vesicles.

2.
Braz. dent. j ; 29(5): 492-499, Sept.-Oct. 2018. tab, graf
Article in English | LILACS | ID: biblio-974174

ABSTRACT

Abstract This study evaluated the effect of different hydrofluoric acid (HF) concentrations on the bond strength between a lithium disilicate-based glass ceramic and a resin cement. Eighty ceramic-blocks (12×7×2 mm) of IPS e.Max CAD (Ivoclar Vivadent) were produced and randomly assigned to 8 groups, considering 2 study factors: HF concentration in 4 levels, i.e., 1% (HF1), 3% (HF3), 5% (HF5), and 10% (HF10), and storage in 2 levels, i.e., baseline (tests were performed 24 h after cementation), and aged (storage for 150 days + 12,000 thermal-cycles at 5°C and 55°C). Acid etching (20 s) was performed, followed by washing, drying, and silanization. Four resin cement cylinders (ϕ= 0.96 mm) were built-up from starch matrices on each ceramic sample (n= 40). Additional ceramic samples were etched and analyzed for contact angle, micro-morphology, and roughness. In baseline condition (without aging), the HF3, HF5, and HF10 groups showed similar bond strength values (13.9 - 15.9 MPa), and HF1 (11.2 MPa) presented lower values than HF5, being that statistically different (p= 0.012). After aging, all the mean bond strengths statistically decreased, being that HF3, HF5, and HF10 (7.8 - 11 MPa) were similar and higher than HF1 (1.8 MPa) (p= 0.0001). For contact angle, HF3, HF5, and HF10 presented similar values (7.8 - 10.4°), lower than HF1 and CTRL groups. HF5 and HF10 presented rougher surfaces than other conditions. For better bond strength results, the tested ceramic may be etched by HF acid in concentrations of 3%, 5%, and 10%.


Resumo Este estudo avaliou o efeito de diferentes concentrações de ácido fluorídrico (HF) na resistência de união entre uma cerâmica vítrea à base de dissilicato de lítio e um cimento resinoso. Oitenta blocos cerâmicos (12×7×2 mm) de IPS e.Max CAD (Ivoclar Vivadent) foram produzidos e distribuídos aleatoriamente em 8 grupos, considerando 2 fatores de estudo: concentração de HF em 4 níveis, isto é, 1% (HF1), 3% (HF3), 5% (HF5), e 10% (HF10), e armazenamento em 2 níveis, isto é, condição inicial (testes foram realizados 24 h após a cimentação), e envelhecidos (150 dias de armazenamento + 12.000 ciclos térmicos a 5°C e 55°C). Condicionamento ácido (20 s) foi realizado, seguido por lavagem, secagem e silanização. Quatro cilindros de cimento resinoso (ϕ= 0.96 mm) foram construídos a partir de matrizes de amido em cada amostra cerâmica (n= 40). Amostras cerâmicas adicionais foram condicionadas e analisadas quanto ao ângulo de contato, micro-morfologia e rugosidade. Na condição inicial (sem envelhecimento), os grupos HF3, HF5, e HF10 mostraram valores de resistência de união similares (13.9 - 15.9 MPa), e HF1 apresentou valores menores que HF5, sendo estatisticamente diferente (p= 0.012). Após o envelhecimento, todas as médias de resistência de união diminuíram estatisticamente, sendo que HF3, HF5 e HF10 foram similares e maiores que HF1 (p= 0.0001). Para o ângulo de contato, HF3, HF5 e HF10 apresentaram valores similares (7.8 - 10.4°), menores que os grupos HF1 e CTRL. HF5 e HF10 apresentaram superfícies mais rugosas que as outras condições. Para melhores resultados de resistência de união, a cerâmica testada pode ser condicionada com ácido fluorídrico nas concentrações de 3%, 5% e 10%.


Subject(s)
Acid Etching, Dental/methods , Ceramics/chemistry , Dental Bonding/methods , Resin Cements/chemistry , Dental Porcelain/chemistry , Hydrofluoric Acid/chemistry , Stress, Mechanical , Surface Properties , Materials Testing , Microscopy, Atomic Force , Shear Strength
3.
Braz. dent. sci ; 19(1): 76-87, 2016. tab, graf
Article in English | LILACS, BBO | ID: lil-785293

ABSTRACT

Objetivo: O objetivo deste estudo foi avaliar o efeito do condicionamento com diferentes concentrações de ácido fluorídrico (AF) na resistência de união ao cisalhamento entre cerâmica feldspática glazeada e bráquetes metálicos. Material e Métodos: Setenta e cinco blocos de cerâmica feldspática glazeada foram produzidos e distribuídos aleatoriamente em 5 grupos: Ctrl- silano; HF1- AF 1% + silano; HF3- AF 3% + silano; HF5- AF 5% + silano; HF10- AF 10% + silano (procedimento padrão: condicionamento por 1 min + lavagem + secagem + silanização). Bráquetes metálicos de incisivo central superior (Edgewise Standard) foram colados sobre a superfície da cerâmica com o uso de um sistema adesivo e resina composta fotopolimerizável (Transbond TM XT, 3M). Os espécimes foram envelhecidos por 60 dias (termociclagem: 10000x a 5-55°C; estocados em água destilada a 37°C). O teste de cisalhamento foi realizado e espécimes foram classificados quanto ao seu Índice de Remanescente Adesivo (IRA). Inspeção topográfica e análise do ângulo de contato da superfície da cerâmica condicionada foram realizados. Dados de resistência adesiva foram analisados estatisticamente usando o teste de Kruskal-Wallis, enquanto os dados de ângulo de contato foram analisados com ANOVA 1-fator e teste de Tukey (p<0.05). Resultados: Nenhuma diferença significativa foi detectada para a resistência de união entre os grupos; mas o condicionamento da superfície teve uma influência significativa sobre os resultados de ângulo de contato (p<0.00001). O grupo controle apresentou a mais alta média de ângulo de contato (61,8± 17,2°). Todos os espécimes apresentaram falhas adesivas na interface cerâmica-resina. Conclusão: As concentrações de AF testadas não influenciaram significativamente a resistência de união de bráquetes metálicos aderidos na superfície de cerâmica feldspática glazeada


Objective: The aim of this study was evaluate the effect of etching with different hydrofluoric acid (HF) concentrations on the shear bond strength between glazed feldspathic ceramic and metal brackets. Material and Methods: –Seventyfive blocks of glazed feldspathic ceramic were produced and randomly allocated to 5 groups: Ctrl- silane application only; HF1- HF1%+silane; HF3- HF3%+silane; HF5- HF5%+silane; HF10 HF10%+silane (standard procedures: etching for 1 min + washing + drying + silanization). Metal brackets for upper central incisors (Edgewise Standard) were bonded on the ceramic surface with the use of an adhesive system and light-cured composite resin (TransbondTM XT, 3M). The specimens were aged for 60 days (thermocycling: 10000x at 5-55 °C; stored in distilled water at 37°C). Shear testing was performed, and specimens were classified for their AdhesiveRemnant-Index (ARI). Topographical inspectionand contact angle analysis of the etched ceramic surfaces were performed. Data were statistically analyzed using the non-parametric Kruskal-Wallis test. One-way ANOVA and post-hoc Tukey’s tests were applied to the contact angle data (p<0.05). Results: No significant difference was detected between the shear bond strength of the groups; but surface etching had a significant influence on the contact angle results (p<0.00001). The control group presented the highest mean contact angle (61.8±17.2°). All specimens showed adhesive failure at the resin ceramic interface. Conclusion The tested HF concentrations did not significantly influence the obtained shear bond strength of metal brackets adhered to glazed feldspathic ceramic surfaces.


Subject(s)
Ceramics , Hydrofluoric Acid , Orthodontic Brackets
SELECTION OF CITATIONS
SEARCH DETAIL